Danger of multiple use of insulin pen needles for diabetic patients
https://doi.org/10.14341/2072-0351-5458
Abstract
To evaluate the risk of multiple use of BD Micro-Fine Plus insulin pen needles in terms of their contamination with microflora, pain and localreaction at the injection site.
Materials and methods.
The study included 45 patients aged above 18 yr with type 1 and 2 diabetes mellitus (DM1 and DM2) treated with shortorultrashort-acting insulins TID. Account was taken of the time each needle was used (once, for 4 and 7 days). Microbiological analysis was madeat the respective time points. Pain sensation after injection was evaluated by patients themselves using a visual-analog scale and severity of local reactionsby the physician.
Results.
Microbial growth was documented in 20 and 33,3% of the patients who used needles ones or many times respectively. Patients of the lattergroup more frequently complained of pain after injection (on day 4, p=0,08) compared with those of the former one (on day 7, p=0,03). Hyperemicfoci at injection sites developed only in case of using the same needle for 4 and 7 days (13,3 and 26,6% respectively).
Conclusion.
Multiple use of insulin pen needles by patients with DM should be avoided since it leads to hyperemia at injection sites, pain sensation,and risk of microbial contamination.
About the Authors
Inna Vladimirovna MisnikovaAlexander Vasil'evich Dreval'
Valeria Alekseevna Gubkina
Irina Vladimirovna Rusanova
References
1. Partanen T.M., Rissanen A. Insulin injection practices //Practical Diabetes Int. 2000; 17(8): Р. 252-254.
2. Dunning T. Insulin delivery devices //Australian Prescriber. 2002; 25: Р. 136-138.
3. Barry H. Ginsberg, and Kenneth Strauss, Has RoboCop Got Diabetes? Response to Berger et al //Diabetes Care , 2004, 27: Р. 1851-1852.
4. Dieter Look and Kenneth Strauss Nadeln mehrfach verwenden? //Diabetes Journal. 1998, 10, Р. 31-34.
5. Kenneth Strauss, Heidi De Gols Irene Hannet, Tuula-Maria Partanen, Anders Frid A pan-European epidemiologic study of insulin injection technique in patients with diabetes //Practical Diabetes International. 2002. Volume 19. Issue 3, Р. 71- 76.
6. Paily R.: Perinephric abscess from insulin syringe reuse //Am. J. Med. Sci., 2004, 327: Р. 47-48.
Review
For citations:
Misnikova I.V., Dreval' A.V., Gubkina V.A., Rusanova I.V. Danger of multiple use of insulin pen needles for diabetic patients. Diabetes mellitus. 2009;12(3):75-77. (In Russ.) https://doi.org/10.14341/2072-0351-5458

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND 4.0).